The Use of Surge Protection with AC
Benefits of “Time Delay Upon Restart”. Learn why surge protection at the outdoor air-conditioning disconnect and a functioning restart time-delay can help protect refrigeration compressors.
The electrical power grid for the United States and Canada is a carefully designed network of generators, transmission lines, substations and distribution lines as power is transmitted to homes and businesses. Unexpected events can create opportunities for transient surge energy to adversely impact air conditioning and other high-value appliances within a home or small business.
This article is intended to help readers understand the benefits of installing surge protection on outside air-conditioning compressors. It also explains the benefits of installing a time-delay-upon-restart protection module on outdoor compressor units.
Protecting Outside Refrigeration Compressors
Most homes being built in southern regions of the country have central air-conditioning systems installed. These systems typically include an “air handler,” which circulates air to rooms throughout the house, and an outdoor refrigeration condenser unit that houses the refrigeration compressor. Mini-split air-conditioning systems are a relatively newer option and are considered efficient for cooling smaller homes because they do not require duct work.
Both central and mini-split air-conditioning systems use a cooling process that compresses refrigerant gas and then cools or heats the home as the high-pressure refrigerant moves through the cooling or heating cycle.
Modern HVAC systems use microprocessor controls to manage operation and ensure proper performance. High-efficiency systems must be carefully controlled to maintain their efficiency ratings. As a result, customers can benefit from having an additional hard-wired surge protector installed at the 240-volt disconnect adjacent to the outdoor condenser/compressor unit. This device complements the meter-base surge protector by protecting against transient surge events that may occur outside.
Customers should also take extra steps to protect HVAC refrigeration compressors from momentary power interruptions. The white paper describes the reasons for this recommendation:
-
During operation, refrigeration compressors compress refrigerant to a high pressure. The high-pressure gas flows through the outside condenser/compressor unit to the indoor air handler and back to the outside unit as part of the refrigeration cycle.
- In cooling mode, cold air is expelled from the air-handler cooling coils into the house, while heat is released from the outdoor compressor-unit coils.
- In heating mode on heat-pump systems, the cycle reverses: hot air is expelled from the indoor heating coils into the house, while cold air is released from the outdoor compressor-unit coils.
-
If power blinks and the compressor stops, power may return a few seconds later and the compressor may attempt to restart while refrigerant pressure is still high. The white paper compares this to starting a car in fifth gear: it can place substantial stress on the compressor and contribute to premature failure.
Time Delay Upon Restart
The white paper describes a straightforward solution for reducing stress on outdoor refrigeration compressors after momentary power interruptions: install a “time delay upon restart” protection module as part of the air-conditioner control system.
Once installed, the module holds the compressor off for 3 to 5 minutes following a momentary power interruption. This allows refrigerant pressure to reduce to a level that supports an easier restart.
Although many HVAC systems have time delays installed and operational, the white paper notes that some installed modules may not be functioning. Having an HVAC service company check the compressor’s time delay and confirm that it works properly is highly recommended.
Combining a functioning time-delay protection module with surge protection at the outdoor disconnect can help protect the system from electrical disturbances and restart stress.
About KENICK, Inc.
KENICK, Inc. has been providing surge protection products and solutions to the electric utility industry since 1989. Its manufacturing facility includes a research laboratory where surge protection products can be tested against small, medium, large and extreme transient surge events.